← RCIS Cardiovascular Invasive Exam Prep (CCI)

FREE STUDY · 6 MIN LESSON

Cardiac Output, Gradients, Valve Area & Shunts

Read the lesson, then use the free narrated cards in the app to check what you remember. Knowledge practice does not replace approved training or any skills evaluation your certifying body requires.

Cardiac Output, Gradients, Valve Area & Shunts

  • You are running the numbers off the case: oxygen samples, gradients, and valve-area math at the console.
  • We walk this domain the way it happens on the floor — one idea at a time.
  • Numbers are taught as ranges and relationships, never single values to memorize.

Clinical teaching details on this slide still need a pinned primary reference and clinical review.

Fick Cardiac Output

  • How does the Fick method calculate cardiac output
  • Fick asks: how much blood must flow to deliver the oxygen the body burned? Wide extraction gap = slow flow = low output.

Clinical teaching details on this slide still need a pinned primary reference and clinical review.

Thermodilution Limits

  • How does thermodilution measure cardiac output, and when does it fail
  • Thermo is fast and easy, but slow or regurgitant blood re-warms the sensor and lies — in low flow, switch to Fick.

Clinical teaching details on this slide still need a pinned primary reference and clinical review.

Gradients Localize

  • What does a pressure gradient across a valve tell you, and how does timing localize the lesion
  • When the gradient appears tells you which valve: systolic LV-to-aorta = aortic stenosis; diastolic LA-to-LV = mitral stenosis.

Clinical teaching details on this slide still need a pinned primary reference and clinical review.

Valve Area vs Gradient

  • Why is valve area, not gradient alone, used to grade stenosis, and what is the Gorlin/Hakki relationship?
  • Low flow can produce a low gradient even in severe aortic stenosis. Gorlin uses flow through the valve during ejection or filling, in mL per second, divided by an empirical coefficient times the square root of the mean gradient in mmHg, giving area in square centimeters. Do not substitute cardiac output in L per minute directly for valve flow. Hakki simplifies the estimate: cardiac output in L per minute divided by the square root of a gradient in mmHg gives area in square centimeters. Mean and peak aortic gradients were studied; use the specified method, not an interchangeable gradient. These are estimates with flow and heart-rate limitations.
  • Gorlin needs valve flow and mean gradient. Hakki needs cardiac output in L per minute. Name the method and units before calculating.

Shunts and Step-Ups

  • How is a left-to-right shunt detected and quantified in the cath lab
  • A saturation "step-up" where it should not rise is arterial blood sneaking in — that jump localizes the left-to-right shunt.

Clinical teaching details on this slide still need a pinned primary reference and clinical review.

The Classic Mix-Up

  • Watch this trap: Thermodilution is the alternative CO method; the exam tests when to switch from thermo to Fick
  • Slow down and name which one the question is actually asking about.

Clinical teaching details on this slide still need a pinned primary reference and clinical review.

Quick Self-Check

  • Before the cards, try this from memory:
  • say whether a wide AV oxygen difference means high or low output, and why valve area beats gradient alone.
  • Then study the cards to confirm your answer.

Clinical teaching details on this slide still need a pinned primary reference and clinical review.

Continue in the app — free module, no card →

What this course covers, sources and pricing →